Russia, 443079, Samara, Avrora st. 114

Phone: (846)

 266-66-66

Search
 Main page  Equipment  Heat pumps  Liquid heat pumps

Heat pumps - Liquid heat pumps

Heat pump model liquid(water)/water

-2

-3

-4

-5

-6

-12

Heating capacity, W *

6,3

9,5

13

15

19

35

Cooling capacity, Q, W **

5,7

8,5

11,3

14,4

17,1

33,1

Refrigerant

R404

R404

R404

R404

R404

R22

Unit model

-ZB15

-ZB21

-ZB30

-ZB38

-ZB45

-SM147

Heat exchanger model

SCE 08 (2)

SCE 15 (2)

SCE 15 (2)

SCE 15 (2)

SCE 23 (2)

SCE 35 (2)

A number of compressors

1

1

1

1

1

1

A number of power stages

1

1

1

1

1

1

A number of circuits

1

1

1

1

1

1

Nominally acceptable water flow, m3/hour

1,0

1,5

2,0

2,5

3,0

5,7

Pressure loss in evaporator,

no more than P

40

40

40

40

40

40

Pumping station model

200 P (20m)

3-50

15-100

15-100

15-100

15-100

15-200

Pumping station model

400 P (40m)

15-100

15-400

15-400

15-400

15-400

15-400

Hydro-module model

200 P

50/3-50

50/15-100

50/15-100

50/15-100

50/15-100

100/15-200

Hydro-module model

400 P

50/15-100

100/15-400

100/15-400

100/15-400

100/15-400

100/15-400

Electric power of heat pump, W ***

1,17

1,75

2,35

2,94

3,32

6,28

Cost of heat pumpwithout pumping station or hydro-module, rub.

160 000

170 000

190 000

200 000

250 000

390 000

Cost of option ,

rub. (per 1 pc)*

30 000

30 000

30 000

30 000

30 000

30 000

Cost of pumping station

200 P (20m)

35 000

40 000

40 000

40 000

40 000

50 000

Cost of pumping station

400 P (40m)

40 000

60 000

60 000

60 000

60 000

60 000

Cost of hydro-module

200 P (20m)

60 000

65 000

65 000

65 000

65 000

85 000

Cost of hydro-module

400 P (40m)

65 000

95 000

95 000

95 000

95 000

95 000


* - Heating capacity is given under conditions Tincoming wtaer = 15°, Toutcoming water = 40/45C

** - Cooling capacityTcondensation =45, T0 =2C

*** - Electrical power of HP is given under conditions of motor/compressor air fans operating 100% out of own capacity under Tcondensation=30, Tboiling=0

Expendables (pipe, cable, insulation) are not included into the cost


Heat pump model liquid(water)/water

-24

-36

-48

-60

-72

Heating capacity, W *

70

109

140

180

218

Cooling capacity, Q, W **

66,2

99,3

132,4

165,5

198,6

Refrigerant

R22

R22

R22

R22

R22

Unit model

-2SM147

-3SM147

-4SM147

-5SM147

-6SM147

Heat exchange model

SCE 70 (2)

SCE 110 (2)

SCE 70

(2 )

SCE110+SCE70

SCE 110

(2 )

A number of compressors

2

3

4

5

6

A number of power stages

2

3

4

5

6

A number of circuits

1

1

2

2

2

Nominally acceptable water flow, m3/hour

12

17

23

29

34

Pressure loss in evaporator,

no more than P

40

40

40

40

40

Pumping station model

200 P (20m)

15-200

15-200

30-200

30-200

30-200

Pumping station model

400 P (40m)

15-400

15-400

30-400

30-400

30-400

Hydro-module model

200 P

100/15-200

100/15-200

300/30-200

300/30-200

300/30-200

Hydro-module model

400 P

100/15-400

100/15-400

300/30-400

300/30-400

300/30-400

Electric power of heat pump, W ***

12,56

18,84

25,12

31,40

37,68

Cost of heat pump without pumping station or hydro-module, rub.

730 000

1 040 000

1 370 000

1 650 000

1 830 000

Cost of option ,

rub. (per 1 pc)*

30 000

30 000

30 000

30 000

30 000

Cost of pumping station

200 P (20m)

50 000

50 000

75 000

75 000

75 000

Cost of pumping station

400 P (40m)

60 000

60 000

100 000

100 000

100 000

Cost of hydro-module

200 P (20m)

85 000

85 000

130 000

130 000

130 000

Cost of hydro-module

400 P (40m)

95 000

95 000

160 000

160 000

160 000


* - Heating capacity is given under conditions Tincoming water = 15, Toutcoming water = 40/45C

** - Cooling capacityT =45, T0 =2C

*** - Electrical power of HP is given under conditions of motor/compressor air fans operating 100% out of own capacity under Tcondensation=30, Tboiling=0

Expendables (pipe, cable, insulation) are not included into the cost

LEADER-S Ltd.

Samara, Avrora st. 114A

tel: (846) 266 66 62

e-mail:illarionov@leader-cool.ru

Heat pump liquid (water)/water components

Unit with scroll compressors “Copeland” and Danfoss

Coaxial heat exchanger

High and low pressure gauge

High-and low-pressure switch

Termoklikson

Sight glass (moisture indicator)

Receiver

Liquid separator

Filter

Danfoss expansion valve

Spider-distributor

Blowing and suction collector (in multicompressor models)

4-way valve (up to 8th model including, from 10th model - as an option)

Check valve 5 pcs (up to 8th model including)

The flow switch

Wiring box

Documentation

Additional options:

- Additional electric heater with a microprocessor

Can not find 'feedback-eq' template with page ''

Application in the fields of

LEADER-S Ltd.

Samara, Avrora st. 114A

tel: (846) 266 66 62

e-mail:illarionov@leader-cool.ru

Heat pump liquid (water)/water components

Unit with scroll compressors “Copeland” and Danfoss

Coaxial heat exchanger

High and low pressure gauge

High-and low-pressure switch

Termoklikson

Sight glass (moisture indicator)

Receiver

Liquid separator

Filter

Danfoss expansion valve

Spider-distributor

Blowing and suction collector (in multicompressor models)

4-way valve (up to 8th model including, from 10th model - as an option)

Check valve 5 pcs (up to 8th model including)

The flow switch

Wiring box

Documentation

Additional options:

- Additional electric heater with a microprocessor

Up