Middle temperature

Middle-temperature double blocks

Model of double block

BB-2

BB-3

BB-4

BB-5

BB-6

Cooling capacity at -10°/+45, kW

3,5

5,3

7,2

9,0

10,6

Voltage, V/phase/Hz

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

RefrigerantR404, kg

2,5

2,7

3,0

5,0

6,0

Operating power consumption of unit, kW *

1,8+0,16

2,5+0,16

3,3+

4,2+

4,8+

Compressor-condensing unit on the basis of scroll motor-compressor Copeland (USA)

Unit standard sizes

1

1

2

2

3

Model of motor-compressor

ZB15

ZB21

ZB30

ZB38

ZB45

Power, ..

2

3

4

5

6

Unit weight netto/gross, kg

62/67

66/71

76/81

101/106

107/112

Unit sizes, length/

width/height, mm

701/568/703

701/568/703

889/760/860

889/760/860

889/760/1100

Heat exchanging surface, m2

24

24

40

40

52

Quantity of condenser fans, pc

1

1

1

1

1

Diameter of condenser fans, mm

450

450

550

550

550

Fans output, m3/hour

5600

5600

8500

8500

8500

Sound pressure, dB

57

57

63

66

67

Unit cooler

Unit cooler model

SE352/1AE

SE352/2AE

SE402/1AE

SE502/1AE

SE502/1AE

Cooling capacity at Tboiling=-8, Tchamber=0, ΔT8, kW

6,1

8,0

11,2

16,2

16,2

Sizes, length/

width/height, mm

1620/330/425

1550/410/455

1550/410/557

1950/480/665

1950/480/665

Defrost type

heater/gas

heater/gas

heater/gas

heater/gas

heater/gas

Power of defrost heaters, pc/kW

1,2

1,53

1,52

1,52

1,52

Power of defrost pan heaters, pc/kW

1,2

1,5

1,5

1,5

1,5

Distance between ribs, mm

4,5

4,5

4,5

4,5

4,5

Heat exchanging surface, m2

30

40

55

80

80

Inner volume, dm3

4,6

8,1

9,5

15,5

15,5

Fans quantity, pc

2

2

2

2

2

Fans diameter, mm

350

350

400

500

500

Output, m3/hour

22500

22500

23000

26000

26000

Jet length (torch), m

10

10

13

15

15

Fans power, W

2120

2120

2180

2550

2550

VoltageV/phase/Hz

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Weight, kg

56

81

102

153

153

Cost, rub.

135 000

150 000

175 000

205 000

225 000

* - Operating power consumption is given under conditions of: R404, +45 C condensation, -10 C boiling point. The first figure - the compressor, the second - the fans of the block.

**- The manufacturer reserves the right to make changes, change parts and assemblies without notifying the customer, which do not impair the declared parameters

Model of double block

BB-12

BB-24

BB-36

BB-48

BB-60

BB-72

Cooling capacity at -10/+45, kW

20,8

41,5

62,3

83,0

103,8

124,6

Voltage, V/phase/Hz

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

RefrigerantR404, kg

11,5

20

29

37

46

55

Operating power consumption of unit, kW *

7,9+

15,8+

23,7

31,6

39,5

47,4

Compressor-condensing unit on the basis of scroll motor-compressor Copeland (USA)

Unit standard sizes

4

5

6

7

8

9

Model of motor-compressor

SM147-4

2SM147-4

3SM147-4

4SM147-4

5SM147-4

6SM147-4

Power, ..

12

24

36

48

60

72

Unit weight netto/gross, kg

306/314

520/530

780/800

1020/1050

1290/1320

1570/1610

Unit sizes, length/

width/height, mm

1580/940/

1170

2300/1100/

2254

3300/1100/

2254

3300/1100/

2254

3900/1100/

2254

3900/1100/

2500

Heat exchanging surface, m2

110

Quantity of condenser fans, pc

2

3

3

3

3

3

Diameter of condenser fans, mm

600

800

800

800

900

900

Fans output, m3/hour

212500

326000

326000

326000

331000

331000

Sound pressure, dB

74

77

77

77

79

79

Unit cooler

Unit cooler model

SE503/2AE

SE554/2AE

2SE554/1AE

2SE554/2AE

2SE604/1AE

4SE554/1AE

Cooling capacity at Tboiling=-8, Tchamber=0, ΔT8, kW

32,8

67,6

105,8

135,2

164

205,6

Sizes, length/

width/height, mm

2900/550/

665

3200/660/

775

22900/620/725

23200/660/

775

23000/660/

985

42900/620/

725

Defrost type

heater

heater

heater

heater

heater

heater

Power of defrost heaters, pc/kW

2,44

1,516

2(1,516)

2(1,516)

2(1,816)

4(1,516)

Power of defrost pan heaters, pc/kW

2,4

1,52

2(1,52)

2(1,52)

2(1,82)

4(1,52)

Distance between ribs, mm

4,5

4,5

4,5

4,5

4,5

4,5

Heat exchanging surface, m2

160

330

2260

2330

2400

4260

Inner volume, dm3

30,4

57,6

251,9

257,6

274,4

451,9

Fans quantity, pc

3

4

24

24

24

44

Fans diameter, mm

500

550

550

550

600

550

Output, m3/hour

36000

48500

2(48500)

2(48500)

2(412000)

2(48500)

Jet length (torch), m

15

15

15

15

15

15

Fans power, W

3550

4600

2(4600)

2(4600)

2(4830)

4(4600)

VoltageV/phase/Hz

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Weight, kg

245

460

2359

2460

2495

4359

Cost, rub.

395 000

685 000

1 080 000

1 350 000

1 650 000

2 100 000

LEADER-S Ltd.

Samara, Avrora st. 114A

tel: (846) 266 66 62

e-mail:illarionov@leader-cool.ru

Due to usage of double units it is possible to save on refrigerant, oil, piping and other expendables to equip big chambers.

This is reached by considerable flexibility of scheduling solutions while using compressor-condensing units of outside discharge. They are put near the unit cooler behind the wall in the street.

That's why it will be more economical and quicker to lay 3 meters of pipeline of the less diameter from the unit cooler to the double unit than to lay the total line from several unit coolers to one central along the whole chamber.

Advantages of double units:

- quick and inexpensive assembling of a refrigeration system;

- modern, effective and reliable compressors;

- condensers with a big extra capacity that are dust and wet proof;

- simple disassembling and transportation to another place.

Can not find 'feedback-eq' template with page ''

Application in the fields of

LEADER-S Ltd.

Samara, Avrora st. 114A

tel: (846) 266 66 62

e-mail:illarionov@leader-cool.ru

Due to usage of double units it is possible to save on refrigerant, oil, piping and other expendables to equip big chambers.

This is reached by considerable flexibility of scheduling solutions while using compressor-condensing units of outside discharge. They are put near the unit cooler behind the wall in the street.

That's why it will be more economical and quicker to lay 3 meters of pipeline of the less diameter from the unit cooler to the double unit than to lay the total line from several unit coolers to one central along the whole chamber.

Advantages of double units:

- quick and inexpensive assembling of a refrigeration system;

- modern, effective and reliable compressors;

- condensers with a big extra capacity that are dust and wet proof;

- simple disassembling and transportation to another place.

Up